Circulation Research · 1964 · 37 citations · 9 references
DentistryOral BiologyDental Pulp BiologyDentin BiologyPulp BiologyDentin PermeabilityPulp PhysiologyDentin Fluid MovementHydraulic Conductance Of DentinHydraulic PermeabilityHydrostatic PressureHydrostatic Pressure DeterminationHydrostatic Pressure MeasurementPressure VariablesPulpal Pressure
The object of these experiments was to evaluate the hydrostatic pressure and hydraulic permeability of the tooth pulp in situ. A small hole was drilled through the enamel and dentin to the dentinal-pulpal junction in canines and third incisors of anesthetized dogs. A threaded cannula filled with mammalian Ringer's solution was screwed into the hole and connected to a microsyringe and a pressure transducer of very low compliance. Pressure was recorded when the cannula was first inserted into the hole; then small amounts of fluid were injected into the system or withdrawn from the system using the micro-syringe. The equilibrium pressure ( P eq ), measured after transients had disappeared, was fairly constant for a given tooth over long periods of time. Referred to tooth level (which was approximately heart level), P eq averaged 57 mm Hg (range 38 to 78 mm Hg) in the ten teeth tested. Superimposed upon the steady value was a random deviation (± 3 mm Hg), a hysteresis effect resulting in a higher pressure if the measurement had been preceded by injection of fluid rather than withdrawal (± 3 mm Hg), and a continuous drift with time ( + 3 mm Hg/hr). The hydrostatic permeability was calculated from the rate of fluid flow when the pressure was above or below its steady state value. When the pressure was high (fluid being forced into the pulp) flow averaged about 0.33 µl/hr-mm Hg over the range P eq to P eq + 20 mm Hg. When the pressure was low (fluid being withdrawn from the tooth), flow averaged about 0.14 µl/hr-mm Hg over the range P eq to P eq - 20 mm Hg. It is concluded that P eq probably represents the true hydrostatic tissue pressure normally existing within the tooth pulp. This implies a high capillary pressure and thus a relatively high resistance in the venous side of the pulp circulation. The interpretation of hydraulic permeability is not certain, but this quantity probably is related to the ease with which fluid passes into or out of the pulp capillaries.
9
Textbook of Medical Physiology
Annals of Internal Medicine · 1966 · 9.8K citations
Life Sciences, Anatomy, Physiology +12
Balint Orban · Southern Medical Journal · 1955 · 463 citations
Textbook of Medical Physiology
Arthur C. Guyton · The American Journal of the Medical Sciences · 1961 · 195 citations
Life Sciences, Anatomy, Physiology +12