Radiology · 2012 · 396 citations · 26 references
EngineeringBioengineeringBiomedical EngineeringBiomedical ImagingNeural EngineeringUltrasonographyBlood-brain Barrier DeliveryBlood-brain Barrier PenetrationContrast-enhanced UltrasonographyContrast-enhanced UltrasoundUltrasonicsUltrasound ImagingBlood-brain Barrier PermeabilityBlood-brain Barrier Permeability ImagingFocus Ultrasound-mediated Bbb DisruptionT1 ContrastT1-weighted ImagingTranscranial Ultrasound ImagingUltrasonic ImagingUltrasound-mediated Permeation
Expected 4 sentences. Let's collect content: Purpose: from first line: "To determine if focused ultrasound disruption of the blood-brain barrier (BBB) can be safely controlled by using real-time modulation of treatment pressures on the basis of acoustic emissions from the exposed microbubbles. All experiments were performed with the approval of the institutional animal care committee." Also maybe other lines? Only first line has Purpose.
To determine if focused ultrasound disruption of the blood-brain barrier (BBB) can be safely controlled by using real-time modulation of treatment pressures on the basis of acoustic emissions from the exposed microbubbles.All experiments were performed with the approval of the institutional animal care committee. Transcranial focused ultrasound (551.5 kHz, 10-msec bursts, 2-Hz pulse repetition frequency, 2 minute sonication) in conjunction with circulating microbubbles was applied in 86 locations in 27 rats to disrupt the BBB. Acoustic emissions captured during each burst by using a wideband polyvinylidene fluoride hydrophone were analyzed for spectral content and used to adjust treatment pressures. Pressures were increased incrementally after each burst until ultraharmonic emissions were detected, at which point the pressure was reduced to a percentage of the pressure required to induce the ultraharmonics and was maintained for the remainder of the sonication. Disruption was evaluated at contrast material-enhanced T1-weighted magnetic resonance (MR) imaging. Mean enhancement was calculated by averaging the signal intensity at the focus over a 3 × 3-pixel region of interest and comparing it with that in nonsonicated tissue. Histologic analysis was performed to determine the extent of damage to the tissue. Statistical analysis was performed by using Student t tests.For sonications resulting in BBB disruption, the mean peak pressure was 0.28 MPa ± 0.05 (standard deviation) (range, 0.18-0.40 MPa). By using the control algorithm, a linear relationship was found between the scaling level and the mean enhancement on T1-weighted MR images after contrast agent injection. At a 50% scaling level, mean enhancement of 19.6% ± 1.7 (standard error of the mean) was achieved without inducing damage. At higher scaling levels, histologic analysis revealed gross tissue damage, while at a 50% scaling level, no damage was observed at high-field-strength MR imaging or histologic examination 8 days after treatment.This study demonstrates that acoustic emissions can be used to actively control focused ultrasound exposures for the safe induction of BBB disruption.
26
Noninvasive MR Imaging–guided Focal Opening of the Blood-Brain Barrier in Rabbits
Kullervo Hynynen, Nathan McDannold, Natalia Vykhodtseva et al. · Radiology · 2001 · 1.5K citations
E.A. Neppiras · Physics Reports · 1980 · 761 citations
Manabu Kinoshita, Nathan McDannold, Ferenc A. Jólesz et al. · Proceedings of the National Academy of Sciences · 2006 · 649 citations · Full text
Nickolai Sheikov, Nathan McDannold, Shipra Sharma et al. · Ultrasound in Medicine & Biology · 2008 · 495 citations · Full text