IEEE Transactions on Power Electronics · 2011 · 475 citations · 21 references
EngineeringElectrical EngineeringElectrochemical EngineeringEnergy SystemsPower ElectronicsBattery SystemsBattery TechnologyConverter TopologiesDc-dc ConversionDc-dc ConvertersEnergy StorageBattery Energy StorageBidirectional Dc-dc ConvertersIsolated ConvertersIsolated Dc-dc ConverterLithium-ion BatteriesMagnetic SaturationMagnetic Saturation AnalysisMagnetic Saturation Effects
This paper describes the design and performance of a 6-kW, full-bridge, bidirectional isolated dc-dc converter using a 20-kHz transformer for a 53.2-V, 2-kWh lithium-ion (Li-ion) battery energy storage system. The dc voltage at the high-voltage side is controlled from 305 to 355 V, as the battery voltage at the low-voltage side (LVS) varies from 50 to 59 V. The maximal efficiency of the dc-dc converter is measured to be 96.0% during battery charging, and 96.9% during battery discharging. Moreover, this paper analyzes the effect of unavoidable dc-bias currents on the magnetic-flux saturation of the transformer. Finally, it provides the dc-dc converter loss breakdown with more focus on the LVS converter.
21
Energy storage systems for advanced power applications
Paulo F. Ribeiro, Brian K. Johnson, Mariesa L. Crow et al. · Proceedings of the IEEE · 2001 · 1.1K citations · Full text