European Journal of Cardio-Thoracic Surgery · 2001 · 50 citations · 7 references
MedicineCardiologySurgeryCardiothoracic SurgeryHemostasisUltrasonographyAnticoagulant TherapyAnticoagulation ManagementAnticoagulation TherapyThromboembolic DiseaseThrombosisThrombosis ManagementDescending Thoracic Aorta ImagingIntracardiac EchocardiographySystemic AnticoagulationTherapeutic AnticoagulationThrombus CharacterizationThrombus Morphology AssessmentThrombus RemovalThrombus Resolution
In a 50-year-old woman, admitted because of a renal infarction, a 10-cm long floating, highly mobile thrombus with a diameter of 15-20 mm in the descending aorta was detected by transoesophageal echocardiography and magnetic resonance imaging. She was a poor surgical candidate due to obstructive lung disease and obesity. Under intravenous heparinization with prothrombin time test values between 80 and 100 s, followed by oral anticoagulation with international normalized ratio values between 3.0 and 4.0, the thrombus resolved after 10 weeks and no recurrence occurred over the next 30 months.
7
Mobile Thromboses of the Aortic Arch Without Aortic Debris
Thierry Laperche, Claude Laurian, R. Roudaut et al. · Circulation · 1997 · 208 citations
Primary Aortic Mural Thrombus: Presentation and Treatment
Tara L. Hahn, Michael C. Dalsing, Alan P. Sawchuk et al. · Annals of Vascular Surgery · 1999 · 74 citations
Medicine, Cardiology, Surgery +12
Recurrent systemic embolization caused by aortic thrombi
Harry R. Aldrich, Leonard N. Girardi, Harry L. Bush et al. · The Annals of Thoracic Surgery · 1994 · 45 citations
Medicine, Internal Medicine, Surgery +14