Applied Industrial Hygiene · 1989 · 11 citations · 1 references
EngineeringIndustrial EngineeringManufacturing EngineeringManufacturing ProcessesProcess ControlVentilationDust ControlDust Exposure ControlEquipment DesignIndustrial VentilationIndustrial Ventilation DesignParticulate MatterBulk Material Dust ControlDust Control DesignDust Control VentilationDust Emission ControlDust SuppressionDust Suppression DesignDust Suppression SystemsFresh Air Supply
Abstract Ventilated booth workstations often do not provide complete dust control during the manual transfer and weigh out of chemical powders. In a typical process, a worker removes powder from the bulk material drum with a scoop, weighs the powder into a paper bag, and then places the full bag into a second drum. A previous study identified points of exposure in a ventilated weigh-out operation at a plastics manufacturing plant. Eddies in front of the worker and inside the weigh-out drum hindered dust control. The depth of the powder in the weigh-out drum also contributed to increased exposures. This follow-up study sought to apply and evaluate three different control modifications of the weigh-out station. The first control was the modification of the worktable to streamline the process. The second control was a local exhaust hood placed at the lip of the bulk material drum. This hood controlled the eddy in the bulk material drum. The last control was an air shower, i.e., a low-velocity, fresh air supply located above the worker. This control counteracted the eddy in front of the worker. In addition to the new controls, the booth air flow rates were varied at one-third and two-thirds of the original flow and full (original) flow. The study design tested the effectiveness of the controls both singly and in combination using real time instrumentation and filter samples. Nine different workers participating in the study performed a total of 77 runs. The results of this study showed some of the tested controls reduced worker dust exposures. The air shower and the local exhaust ventilation resulted in a reduction of exposures. The modified worktable had no significant effect on exposures. Further, this study showed that with the air shower installed, booth flow rates of one-third flow can control worker dust exposures. A recommended configuration would include the air shower, the local exhaust ventilation, and one-third booth flow. An economic analysis showed that the cost savings incurred by this configuration would result in a payback period of about 4.5 years. The recommended configuration, while reducing costs, will result in a reduction of worker dust exposures.
1