IEEE Transactions on Industry Applications · 1992 · 46 citations · 5 references
EngineeringElectrical EngineeringElectric MachinesMotor ControlPower ElectronicsBrushless Dc MachinesDirect Current MachinesDrive SystemsElectric DrivesElectric Motor DrivesElectric MotorsDynamic ResponseFlux LinkagePhase AngleReluctance MachinesReluctance MotorsSynchronous Reluctance MachinesSynchronous Reluctance MotorsTorque Production
The authors examine operating modes of the cageless reluctance motor and propose a new control method for quick torque response. It is shown that the control of sinusoidal phase current in magnitude with fixed current phase angle provides a simple means for achieving quick torque response and efficient operation. The flux linkage, current, torque. and the rated voltage of the inverter are calculated for a reluctance motor. A performance comparison is made between the proposed control method and the field-oriented control method. Analysis and computer simulation show that substantial improvements in dynamic response and efficiency are achieved for a reluctance motor when operated with constant current phase angle compared with operation at constant direct axis current or constant flux. Test data from a 24000 r/min. 1.3 kW reluctance motor drive system are provided.< <ETX xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">></ETX>
5