Natural SciencesMaterials EngineeringMaterials ScienceCorrosion ScienceElectrochemistryMetallurgyCorrosion EngineeringCorrosion MechanismsCorrosion Of SteelsCorrosion TestingLocalized CorrosionStress Corrosion CrackingCorrosion MorphologyCrackingElectrochemical MeasurementsLocalized Corrosion Of Stainless SteelsSaturated Calomel ElectrodeSlow Strain Rate TestingStainless Steel CorrosionTransgranular Stress Corrosion Cracking
The slow strain rate test (SSRT) technique was applied to AISI 304 stainless steel (SS) in neutral and acidic NaCI solutions to define the laboratory test conditions suitable for inducing transgranular stress corrosion cracking (TGSCC). By electrochemical measurements and metallographic observations, it was recognized that localized corrosion (pitting and/or crevice corrosion) is the first step of the cracking mechanism at pH > dpH (the depassivation pH value). The evolution of the corrosion morphology from pitting to cracking is determined by a critical extension rate at a given pH value of the solution. TGSCC was prevented, as previously demonstrated for localized corrosion, by applying external controlled cathodic protection in a well-defined potential range in which the free surface remains passive while occluded cells are deactivated. For AISI 304, this range has the following limits: from −450 to −660 mV vs SCE (saturated calomel electrode).
4