End RegionFull Three-dimensional StructuresElectrical EngineeringElectric MachineEngineeringMagnetic Vector PotentialWind Power GenerationMagnetohydrodynamicsHuge Turbine-generatorsComputational ElectromagneticsPropulsionWind Turbine ModelingGas Turbine EngineFluid Machinery
This paper presents a novel strategy to model the full three-dimensional structures of end region of huge turbine-generators with power level up to 1000MW. The 3-D nonlinear anisotropic magnetic field including the eddy current losses is calculated by utilizing the reduced magnetic vector potential formulation. With the help of Biot-Savart's law, the magnetic field caused by currents in the stator and rotor windings, which are very complex in geometric shapes, can be calculated in a far easy way. The flux density distribution in the end region and the eddy current distribution in the structural parts under different operating conditions are presented.