Optics Express · 2004 · 72 citations · 0 references
EngineeringNeurobiologyNeuroscienceBiomedical OpticsBiophotonicsNeurophysiologyAction Potential DynamicsBiopotential MeasurementNeural Recording TechnologiesNeural Signal AcquisitionOptical SensingOptical SensorsAction Potential PropagationNon-contact MeasurementNoninvasive SensingOptical Displacement MeasurementOptical Displacement SensorsOptical Neural RecordingSpontaneous Neural ActivitySurface Displacement Mapping
We demonstrate non-contact sub-nanometer optical measurement of neural surface displacement associated with action potential propagation. Experimental results are recorded from nerve bundles dissected from crayfish walking leg using a phase-sensitive optical low coherence reflectometer. No exogenous chemicals or reflection coatings are applied. Transient neural surface displacement is less than 1 nm in amplitude, 1 ms in duration and is coincident with action potential arrival to the optical measurement site. Because the technique uses back-reflected light, noninvasive detection of various neuropathies may be possible.