American Journal of Roentgenology · 2011 · 208 citations · 25 references
MedicineOrthopaedic SurgeryOrthopedic SurgeryDiagnostic ImagingDiagnostic RadiologyOrthopedicsImaging AssessmentJoint SurgeryMagnetic Resonance ImagingMedical ImagingMusculoskeletal ImagingOrthopedic ImagingArtifact ReductionHip Arthroplasty OsteolysisJoint Synovitis ImagingMetal Artifact ReductionMusculoskeletal Magnetic Resonance ImagingPostoperative Synovitis EvaluationSynovial ImagingTendon Tear Evaluation
OBJECTIVE: The goal of this study was to evaluate the quality of images obtained with a prototype imaging technique, multiacquisition variable-resonance image combination (MAVRIC), compared with fast spin-echo (FSE) images in the evaluation of patients who have undergone hip, shoulder, or knee arthroplasty. MATERIALS AND METHODS: MRI with metal-artifact reduction FSE and MAVRIC sequences was performed in the care of 122 patients who had undergone 74 hip, 27 shoulder, and 21 knee arthroplasties. The FSE and MAVRIC images were subjectively graded for visualization of the synovium, prosthesis-bone interface, and hip abductors or supraspinatus tendon. The presence of synovitis, osteolysis, or supraspinatus tendon tear was recorded. RESULTS: Visualization of the synovium was significantly better on MAVRIC images than on FSE images of the hip (p < 0.0001), shoulder (p < 0.01), and knee (p < 0.01). Synovitis was detected only on the MAVRIC images of nine subjects (12%) who had undergone hip arthroplasty and five subjects (18%) who had undergone shoulder arthroplasty. Visualization of the periprosthetic bone was significantly better on MAVRIC images of the hip (p < 0.0001), shoulder (p < 0.0001), and knee (p < 0.01). Osteolysis was detected only on the MAVRIC images of 12 subjects (16%) who had undergone hip arthroplasty, six (22%) who had undergone shoulder arthroplasty, and five (24%) who had undergone knee arthroplasty. Visualization of the supraspinatus tendon was significantly better on MAVRIC images (p < 0.0001). Supraspinatus tendon tears in 12 subjects (44%) were detected only on MAVRIC images. CONCLUSION: MAVRIC complements the information on FSE images after arthroplasty and is a useful additional sequence, particularly when there is concern about synovitis, periprosthetic osteolysis, or the presence of a supraspinatus tendon tear.
25
SEMAC: Slice encoding for metal artifact correction in MRI
Wenmiao Lu, Garry E. Gold, John M. Pauly et al. · Magnetic Resonance in Medicine · 2009 · 388 citations · Full text
Imaging near metal with a MAVRIC‐SEMAC hybrid
Kevin M. Koch, Anja Brau, Weitian Chen et al. · Magnetic Resonance in Medicine · 2010 · 227 citations
Complications of Total Hip Arthroplasty: MR Imaging—Initial Experience
Lawrence M. White, Jae K. Kim, Mitesh Mehta et al. · Radiology · 2000 · 227 citations
MAGNETIC RESONANCE IMAGING AFTER TOTAL HIP ARTHROPLASTY
Hollis G. Potter, Bryan J. Nestor, Carolyn M. Sofka et al. · Journal of Bone and Joint Surgery · 2004 · 224 citations