Journal of Nuclear Medicine Technology · 2007 · 37 citations · 13 references
MedicineNuclear MedicineRadiologyCardiac Nuclear MedicineDiagnostic ImagingDiagnostic Nuclear MedicineCardiac ImagingCardiac Nuclear ImagingCardiovascular ImagingElectrocardiographyMyocardial Perfusion ImagingCardiac Myocardial Perfusion ImagingMyocardial Perfusion ScintigraphyNegative Predictive Value AssessmentPositive Predictive ValueRest Myocardial Perfusion Imaging
UNLABELLED: Emergency department (ED) patients with chest pain (CP) and a nondiagnostic electrocardiogram (ECG) present difficult management decisions. The purpose of this study was to investigate the utility of resting radionuclide SPECT myocardial perfusion imaging (SPECT MPI)-including an overnight delayed image acquisition protocol-in identifying patients presenting to the ED with CP at risk for cardiac events. METHODS: Patients presenting to the ED with CP and a nondiagnostic ECG were prospectively enrolled and underwent chest pain center evaluation. All patients also underwent resting gated SPECT MPI using (99m)Tc-tetrofosmin tracer. Patients presenting on weeknights between 12 am and 6 am had tracer injection in the ED with image acquisition delayed until later in the morning. Patients were monitored for a 30-d occurrence of cardiac events. RESULTS: Over a 16-mo period, 479 patients were enrolled and completed follow-up. For the prediction of 30-d cardiac events, resting SPECT MPI demonstrated a sensitivity and a specificity of 76.9% and 92.4%, respectively. Positive and negative predictive values were 22.2% and 99.3%, respectively. Among the 3 patients with a normal perfusion scan who suffered cardiac events, all had tracer injection several hours after resolution of CP. The overnight delayed image acquisition protocol provided a negative predictive value of 100% for the 44 patients whose image acquisition was delayed until the following morning. CONCLUSION: A normal resting SPECT MPI in ED patients presenting with CP predicts a very low occurrence of 30-d cardiac events. A delayed image acquisition protocol did not decrease the accuracy of SPECT MPI. Such a protocol may be useful in increasing the availability of this imaging modality.
13
Missed Diagnoses of Acute Cardiac Ischemia in the Emergency Department
Jennifer Pope, Tom P. Aufderheide, Robin Ruthazer et al. · New England Journal of Medicine · 2000 · 1.8K citations · Full text
Michael C. Kontos, Robert L. Jesse, Kristin L Schmidt et al. · Journal of the American College of Cardiology · 1997 · 194 citations
Missed Diagnoses of Acute Cardiac Ischemia in the Emergency Department
Hector J. Pope, Tom P. Aufderheide, Robin Ruthazer et al. · Survey of Anesthesiology · 2000 · 142 citations