Magnetic Resonance in Medicine · 2000 · 95 citations · 19 references
MedicineBioengineeringRadiologyDiagnostic ImagingDiagnostic RadiologyUltrasonographyDiffusion ImagingMagnetic Resonance ImagingMedical ImagingObstetric UltrasonographyPlacental ImagingPlacental UltrasonographyEcho Planar ImagingEffective Diffusion CoefficientGradient Echo SequencesImaging Time OptimizationIntravoxel Incoherent Motion ImagingPlacental Blood FlowPlacental Diffusion ImagingSpin Echo
This paper presents the first in vivo measurements of intravoxel incoherent motion in the human placenta, obtained using the pulsed gradient spin echo (PGSE) sequence. The aims of this study were two-fold. The first was to provide an initial estimate of the values of the IVIM parameters in this organ, which are currently unknown. The second aim was then to use these results to optimize the sequence timings for future studies. The moving blood fraction (f), diffusion coefficient (D), and pseudo-diffusion coefficient (D*) were measured. The average value of f was 26 +/- 6 % (mean +/- SD), D was 1.7 +/- 0.5 x 10(-3) mm2/sec, and D* was 57 +/- 41 x 10(-3) mm2/sec. For the optimized values of b, the expected percentage uncertainty in the fitted values of f, D, and D* for the placenta were sigmaf/f = 14.9%, sigmaD/D = 14.3%, sigmaD*/D* = 44.9%, for an image signal-to-noise of 20:1, and a total imaging time of 800 sec.
19
Denis Le Bihan, D Lallemand, P. Grenier et al. · Radiology · 1986 · 3.9K citations
Separation of diffusion and perfusion in intravoxel incoherent motion MR imaging.
Denis Le Bihan, D Lallemand, Michèle Aubin et al. · Radiology · 1988 · 3.2K citations