Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · 2006 · 14 citations · 12 references
EngineeringBioengineeringBiomedical EngineeringBiosensorsMicroelectromechanical SystemsSensorsBiomedical SensorsFiber OpticsIntracranial Pressure MonitoringMedical InstrumentationOptical SensorsPressure SensorsFiber-optic Pressure SensorsFiber-optic SensorsFiber-optic Temperature SensorsIntra-aortic Balloon PumpingMicro-optical SensorsMiniaturized Temperature SensorsOptical Pressure SensorsPressure Transduction
We present how fiber-optic temperature or pressure sensors could be applied to minimally invasive diagnostics and therapies. For instance a miniature pressure sensor based on micro-optical mechanical systems (MOMS) could solve most of the problems associated with fluidic pressure transduction presently used for triggering purposes. These include intra-aortic balloon pumping (IABP) therapy and other applications requiring detection of fast and/or subtle fluid pressure variations such as for intracranial pressure monitoring or for urology diagnostics. As well, miniature temperature sensors permit minimally invasive direct temperature measurement in diagnostics or therapies requiring energy transfer to living tissues. The extremely small size of fiber-optic sensors that we have developed allows quick and precise <i>in situ </i>measurements exactly where the physical parameters need to be known. Furthermore, their intrinsic immunity to electromagnetic interference (EMI) allows for the safe use of EMI-generating therapeutic or diagnostic equipments without compromising the signal quality. With the trend of ambulatory health care and the increasing EMI noise found in modern hospitals, the use of multi-parameter fiber-optic sensors will improve constant patient monitoring without any concern about the effects of EMI disturbances. The advantages of miniature fiberoptic sensors will offer clinicians new monitoring tools that open the way for improved diagnostic accuracy and new therapeutic technologies.
12
Significance of intracranial hypertension in severe head injury
J. Douglas Miller, Donald P. Becker, John D. Ward et al. · Journal of neurosurgery · 1977 · 797 citations
Medicine, Neurosurgery, Surgery +16
Initial Clinical Experience With Intraaortic Balloon Pumping in Cardiogenic Shock
Ádrian Kantrowitz · JAMA · 1968 · 754 citations
Medicine, Cardiology, Surgery +16
Direct Blood Pressure Measurement —Dynamic Response Requirements
Reed M. Gardner · Anesthesiology · 1981 · 520 citations · Full text