IEEE Transactions on Nuclear Science · 2006 · 46 citations · 9 references
Natural SciencesRadiologyDiagnostic ImagingRadiation DetectionRadiation MeasurementDetector TechnologyGamma-ray DetectionGamma-ray DetectorsGamma-ray InstrumentationGamma-ray SourcesRadiation Imaging DetectorsCoded Aperture ImagingCoded-aperture Imaging DetectorsDetector Array DesignGamma-ray ImagingImaging ResolutionPoint SourcesPoint-source DetectionSearch Sensitivity
We have recently completed a large-area, coded-aperture, gamma-ray imager for use in searching for radiation sources. The instrument was constructed to verify that weak point sources can be detected at considerable distances if one uses imaging to overcome fluctuations in the natural background. The instrument uses a rank-19, one-dimensional coded aperture to cast shadow patterns onto a 0.57 m/sup 2/ NaI(Tl) detector composed of 57 individual cubes each 10 cm on a side. These are arranged in a 19/spl times/3 array. The mask is composed of four-cm thick, one-meter high, 10-cm wide lead blocks. The instrument is mounted in the back of a small truck from which images are obtained as one drives through a region. Results of first measurements obtained with the system are presented.
9
William H. Press, Saul A. Teukolsky, William T. Vetterling et al. · 1994 · 15.4K citations
New family of binary arrays for coded aperture imaging
Stephen R. Gottesman, E. E. Fenimore · Applied Optics · 1989 · 532 citations
Multiplex imaging with multiple-pinhole cameras
Chris Brown · Journal of Applied Physics · 1974 · 65 citations
Arts, Astronomy, Biomedical Imaging +11