Radiology · 1991 · 377 citations · 0 references
MedicineRadiologyDiagnostic ImagingDiagnostic RadiologyHepatologyBiliary Tract DiseaseGastrointestinal ImagingGastrointestinal RadiologyHepatobiliary DiseaseHepatobiliary ImagingMagnetic Resonance ImagingBile Duct ImagingBiliary Dilatation AssessmentGradient Echo SequencesIntrahepatic Bile Duct AnatomyMagnetic ResonanceNoninvasive DiagnosticsObstructive JaundiceT2-weighted Imaging
Limited spatial resolution, partial volume effects, and bile flow limit MR cholangiography’s ability to delineate the biliary tract, and further technical advances are needed to improve image quality. The study employed a heavily T2‑weighted gradient‑echo sequence acquired in sagittal and coronal planes during breath‑hold intervals, with maximum‑intensity projection post‑processing, on five volunteers and 13 obstructive jaundice patients. MR cholangiography successfully visualized the biliary ducts in 11 of 13 patients, delineated obstruction level and dilatation grade, but identified the cause of obstruction only in eight cases and failed to image the distal tract; in volunteers it demonstrated anatomy in only two subjects, suggesting it may be a useful adjunctive tool for noninvasive evaluation of obstructive jaundice.
A heavily T2-weighted gradient-echo sequence was used for magnetic resonance (MR) imaging of the biliary system in five healthy volunteers and 13 patients with obstructive jaundice. Images were obtained in the sagittal and coronal planes during sequential breath-hold intervals and were post-processed by using a maximum-intensity projection algorithm. The extrahepatic and intrahepatic bile ducts were well visualized in 11 patients. The level of obstruction and the grade of dilatation were depicted with MR cholangiography. However, the cause of obstruction could be determined with MR cholangiography in only eight cases. The part of the biliary system below the obstruction could not be visualized with MR cholangiography. In the volunteers, MR cholangiography could demonstrate the anatomy of the biliary tract in only two subjects. Possible causes for this phenomenon are the limited spatial resolution of MR imaging, partial volume effects, or flow within the bile ducts. MR cholangiography may be a useful adjunctive tool for noninvasive evaluation of patients with obstructive jaundice. However, further technical advances are necessary to improve image quality.