IEEE Transactions on Power Delivery · 1992 · 34 citations · 0 references
Natural SciencesElectrical EngineeringMaterials ScienceMechanical Behavior Of MaterialsPapermakingPolymer MaterialsDielectric MaterialsDielectric PropertiesDielectricsElectrical ConductivityInsulation MaterialsInsulation SystemsBreakdown StrengthCable InsulationCapacitanceElectrical Breakdown StrengthElectrical Insulation MaterialsInsulation DesignSynthetic InsulationThickness Dependence
The electrical characteristics and insulation design strength of liquid-nitrogen-impregnated synthetic insulation were considered. The impregnation of liquid nitrogen into insulation paper can be monitored by measuring the electrostatic capacitance of the cable. in tan delta , an index of the dielectric loss, was 0.31% for cellulose paper and 0.18% for semisynthetic paper, polypropylene laminated semisynthetic paper, and biaxially oriented polypropylene laminated paper. It was found that the decline of the thickness dependence of the breakdown strength of the liquid-nitrogen-impregnated insulating cable was steeper than that of the oil-filled cables. It is possible to design the insulation strength of the 66 kV cable to be 10 kV/mm.< <ETX xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">></ETX>