2003 · 17 citations · 11 references
EngineeringElectrical EngineeringElectric MachinesPower ElectronicsPowertrain EngineeringDrive SystemsElectric DrivesElectric Motor Drive SystemsElectric Motor DrivesElectric MotorsLosses In Electric MachinesCurrent LeadsLoss AnalysisMotor Drive ApplicationsMotor Drive InvertersMotor Drive Power ElectronicsMotor Drive SystemsMotor LossesSystem Losses
This paper presents an evaluation of inverter and cable losses in adjustable speed drive systems with long motor leads. Analyses and simulations were conducted to determine the motor/drive system losses as a function of cable length, switching frequency and loading conditions. Simulation and experimental results are presented for 5 kVA, 20 kVA and 30 kVA motor/drive systems at switching frequencies of 2 kHz, 6 kHz and 10 kHz and cable lengths of 10 ft and 300 ft. Results show the need for possible inverter derating with long cables at higher switching frequencies.
11