2003 IEEE Nuclear Science Symposium. Conference Record (IEEE Cat. No.03CH37515) · 2003 · 15 citations · 15 references
EngineeringMaterials SciencePhysicsNuclear InstrumentationPhotonicsRadiation DetectionDetector TechnologyPositron Emission TomographyRadiation DetectorsRadiation Imaging DetectorsScintillator MaterialsDecay TimeDetector Array DesignDetector ConstructionDetector DesignDetector Energy ResolutionImaging DetectorsPet Detector TechnologyRadiation Energy Resolution
Recent improvements in the growth and packaging of lanthanum bromide (LaBr/sub 3/) in addition to its superb intrinsic properties of high light output, excellent energy resolution, and fast decay time, make it a viable detection material for a PET scanner based on time-of-flight (TOF). We have utilized theoretical simulations and experimental measurements to investigate the design and performance of pixilated LaBr/sub 3/ Anger-logic detectors suitable for use in a TOF PET scanner. Our results indicate that excellent energy resolution can be obtained from individual as well as multicrystal arrays of LaBr/sub 3/ in a 4/spl times/4/spl times/30 mm/sup 3/ geometry. Measured energy resolutions (at 511 keV) of 4.3% for a single crystal and an average of 5.31% for an array of 100 crystals have been achieved. Both simulations and experimental measurements of an Anger-logic based detector consisting of the LaBr/sub 3/ crystal array coupled to a continuous light guide and seven PMTs, have resulted in the ability to clearly discriminate 511 keV interactions in each crystal. We have measured coincidence time resolutions for both 0.5% and 5.0% Ce-doped LaBr/sub 3/ and found that the higher level of Ce-doping yielded superior results with little to no degradation in light output or energy resolution. The time resolution for a single 5.0% Ce-doped LaBr/sub 3/ crystal coupled directly to a PMT was measured to be 275 ps. With a 25 crystal array coupled to a light guide and seven PMT cluster an average time resolution of 308 ps was obtained by summing the signals from the PMT cluster. Ultimately, 5.0% and 0.5% Ce-doped LaBr/sub 3/ Anger-logic detectors placed in coincidence yielded a time resolution of approximately 505 ps.
15
High-energy-resolution scintillator: Ce3+ activated LaBr3
Edgar van Loef, P. Dorenbos, C.W.E. van Eijk et al. · Applied Physics Letters · 2001 · 655 citations
High-energy-resolution scintillator: Ce3+ activated LaCl3
Edgar van Loef, P. Dorenbos, C.W.E. van Eijk et al. · Applied Physics Letters · 2000 · 534 citations
Engineering, Chemistry, Photonics +15