EP Europace · 2015 · 18 citations · 22 references
MedicineCardiologyCardiothoracic SurgeryClinical CardiologyInterventional CardiologyAtrial ElectrophysiologyAtrial FibrillationCardiac ArrhythmiasCatheter AblationHemodynamicsLeft Ventricular Function AssessmentAnnular VelocityDiastolic Function EvaluationLeft Atrial FunctionLeft Atrial RemodelingLeft Ventricular PhysiologyLeft Ventricular Systolic FunctionSystolic DysfunctionVentricular Diastolic Function
AIMS: Successful rhythm control after atrial fibrillation catheter ablation is known to induce left atrial reverse remodelling and improve left ventricular (LV) function. We explored the clinical factors affecting LV systolic and diastolic function 1-year after catheter ablation for atrial fibrillation. METHODS AND RESULTS: We compared pre-procedural and 1-year follow-up echocardiograms in 521 patients with atrial fibrillation who underwent catheter ablation. Left ventricular systolic function was estimated by the ejection fraction (EF); diastolic function was estimated by the ratio of early transmitral flow velocity (E) to early mitral annular velocity (Em). (i) Catheter ablation of atrial fibrillation significantly reduced left atrium volume index (P < 0.001) and improved LV EF both in patients with recurrent atrial fibrillation (n = 133, P = 0.008) and those without recurrence (n = 388, P < 0.001). (ii) Follow-up EF was significantly improved in patients with baseline E/Em < 15 (n = 454, P < 0.001), whereas E/Em was significantly reduced in patients with pre-procedural E/Em ≥ 15 (n = 67, P = 0.008). (iii) Baseline E/Em < 15 (β = -3.854, 95% CI -5.99 to -1.72, P < 0.001), baseline EF <50% (β = 10.586, 95% CI 7.55 to 13.63, P < 0.001), and female (β = -1.726, 95% CI -3.36 to -0.10, P = 0.038) were independently associated with improved EF. Baseline E/Em ≥ 15 (β = 4.896, 95% CI 3.45 to 6.34, P < 0.001) and younger age (β = -0.066, 95% CI -0.11 to -0.02, P = 0.003) were independent factors associated with improved E/Em. CONCLUSION: Pre-procedural E/Em predicted improvement in LV systolic and diastolic functions 1 year after catheter ablation for atrial fibrillation. Low baseline E/Em was independently associated with improved EF, while high E/Em predicted improvement in LV diastolic function.
22
2013 ACCF/AHA Guideline for the Management of Heart Failure
Clyde W. Yancy, Mariell Jessup, Biykem Bozkurt et al. · Journal of the American College of Cardiology · 2013 · 12.6K citations
Roberto M. Lang, Michelle Bierig, Richard B. Devereux et al. · Journal of the American Society of Echocardiography · 2005 · 11.3K citations
2012 focused update of the ESC Guidelines for the management of atrial fibrillation
A. John Camm, Gregory Y.H. Lip, Raffaele De Caterina et al. · EP Europace · 2012 · 3.8K citations · Full text