IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control · 1998 · 155 citations · 62 references
Natural SciencesBiomedical EngineeringBiomedical ImagingDiagnostic ImagingUltrasoundFourier OpticsImagingMedical ImagingMedical Imaging PhysicsUltrasound ImagingUltrasound PhysicsB-mode ImagingDiffraction ImagingDiffraction-limited ImagingDiffraction-limited ResolutionFourier ReconstructionPlane Wave PropagationSignal-to-noise RatioUltrasound Image Acquisition
Limited diffraction beams have a large depth of field and have many potential applications. Recently, a new method (Fourier method) was developed with limited diffraction beams for image construction. With the method and a single plane wave transmission, both 2D (two-dimensional) and 3D (three-dimensional) images of a very high frame rate (up to 3750 frames/s for a depth of 200 mm in biological soft tissues) and a high signal-to-noise ratio (SNR) can be constructed with relatively simple and inexpensive hardware. If limited diffraction beams of different parameters are used in both transmission and reception and transducer aperture is shaded with a cosine function, high-resolution and low-sidelobe images can be constructed with the new method without montage of multiple frames of images [the image quality is comparable to that obtained with a transmit-receive (two-way) dynamically focused imaging system]. In this paper, the Fourier method was studied with both experiment and computer simulation for 2D B-mode imaging. In the experiment, two commercial broadband 1D array transducers (48 and 64 elements) of different aperture sizes (18.288 and 38.4 mm) and center frequencies (2.25 and 2.5 MHz) were used to construct images of different viewing sizes. An ATS539 tissue-equivalent phantom of an average frequency-dependent attenuation of 0.5 dB/MHz/cm was used as a test object. To obtain high frame rate images, a single plane wave pulse (broadband) was transmitted with the arrays. Echoes received with the arrays were processed with both the Fourier and conventional dynamic focusing (delay-and-sum) methods to construct 2D B-mode images. Results show that the quality (resolution and contrast) of constructed images is virtually identical for both methods, except that the Fourier method is simpler to implement. Both methods have also a similar sensitivity to phase aberration distortions. Excellent agreement among theory, simulation, and experiment was obtained.
62
Methods of Theoretical Physics
Philip Μ. Morse, Herman Feshbach, E. L. Hill · American Journal of Physics · 1954 · 13.3K citations
Methods of theoretical physics
Caterina Domenicali · Journal of the Franklin Institute · 1954 · 4.9K citations
J. Durnin, Joseph J. Miceli, J. H. Eberly · Physical Review Letters · 1987 · 3.6K citations
Natural Sciences, Physics, Optics +13
The Axicon: A New Type of Optical Element
John H. McLeod · Journal of the Optical Society of America · 1954 · 964 citations
Natural Sciences, Physics, Optics +10