BioMedical Engineering OnLine · 2010 · 19 citations · 11 references
MedicineOrthopaedic SurgeryOrthopedic SurgeryBiomechanicsOrthopedicsTribologyArthroplasty BiomechanicsImplant BiomechanicsJoint BiomechanicsJoint MechanicsKnee BiomechanicsTribological MaterialsKnee Joint MechanicsMaterial Wear AnalysisRollingTotal Knee Arthroplasty BiomechanicsWearWear MechanicsWear SimulationWear Testing
BACKGROUND: Material wear testing is an important technique in the development and evaluation of materials for use in implant for total knee arthroplasty. Since a knee joint induces a complex rolling-gliding movement, standardised material wear testing devices such as Pin-on-Disc or Ring-on-Disc testers are suitable to only a limited extent because they generate pure gliding motion only. METHODS: A rolling-gliding wear simulator was thus designed, constructed and implemented, which simulates and reproduces the rolling-gliding movement and loading of the knee joint on specimens of simplified geometry. The technical concept was to run a base-plate, representing the tibia plateau, against a pivoted cylindrical counter-body, representing one femur condyle under an axial load. A rolling movement occurs as a result of the friction and pure gliding is induced by limiting the rotation of the cylindrical counter-body. The set up also enables simplified specimens handling and removal for gravimetrical wear measurements. Long-term wear tests and gravimetrical wear measurements were carried out on the well known material pairings: cobalt chrome-polyethylene, ceramic-polyethylene and ceramic-ceramic, over three million motion cycles to allow material comparisons to be made. RESULTS: The observed differences in wear rates between cobalt-chrome on polyethylene and ceramic on polyethylene pairings were similar to the differences of published data for existing material-pairings. Test results on ceramic-ceramic pairings of different frontal-plane geometry and surface roughness displayed low wear rates and no fracture failures. CONCLUSIONS: The presented set up is able to simulate the rolling-gliding movement of the knee joint, is easy to use, and requires a minimum of user intervention or monitoring. It is suitable for long-term testing, and therefore a useful tool for the investigation of new and promising materials which are of interest for application in knee joint replacement implants.
11
Does the femur roll-back with flexion?
V. Pinskerová, P. Johal, S. Nakagawa et al. · Journal of Bone and Joint Surgery - British Volume · 2004 · 243 citations · Full text
Jim Nevelos, Eileen Ingham, Christina Doyle et al. · Journal of Materials Science Materials in Medicine · 2001 · 90 citations