IEEE Transactions on Energy Conversion · 1991 · 17 citations · 9 references
EngineeringElectrical EngineeringCircuit TheoryElectric MachinesPower ElectronicsCurrent-voltage CharacteristicsPower SystemsSynchronous MachinesArmature Reaction In Synchronous Machines
A method for determining the armature leakage reactance of synchronous machines is presented. In this method, the terminal voltage/armature current characteristic with the machine unloaded and unexcited is needed, together with the open-circuit characteristic of the machine. The armature leakage reactance is derived from these two curves using an iterative technique. The armature leakage reactances of five synchronous machines of different designs are obtained using this method. Their values are compared with those of the Potier reactance of these machines measured at various terminal voltages.< <ETX xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">></ETX>
9