International Conference on Mathematical Methods and Computational Techniques in Electrical Engineering · 2005 · 17 citations · 4 references
EngineeringElectrical EngineeringElectric MachinesPower ElectronicsRenewable Energy SystemsAc-dc ConvertersActive FiltersElectric DrivesElectric Motor DrivesPower QualityThree-phase CircuitsActive Power FilterCurrent UnbalanceCurrentsHarmonic ReductionHarmonicsHvdc TransmissionReactive Power CompensationReactive Power Control
Use of nonlinear loads, such as thyristor controlled inductors for FACTs devices, converters for HVDC transmission and large adjustable speed motor drives, is expected to grow rapidly. All of these loads inject harmonic currents and reactive power into the power system. This paper presents a new control scheme for a 3 phase parallel active filter. The presented control system is able to compensating current harmonics, reactive power and current unbalance of non linear loads. The conventional controllers based on pq theory need more calculations, since they need the use of Clark transformation (abc to αβ transformation). The proposed control system is very simple and therefore practical implementation of active filters is available. The presented simulation and experimental results show the validity of control strategy. In this paper the PSCAD/EMTDC program and LAB VIEW software are used for simulation and hardware implementation, respectively.
4