Journal of Clinical Microbiology · 2006 · 23 citations · 23 references
Life SciencesInfectious DiseasesMicrobiologyMolecular DiagnosticsMolecular VirologyVirologyHiv DiagnosisHiv TestingInfectious Disease Molecular TestingRna-based DiagnosticsViral DiagnosticsViral InfectionsHiv Nucleic Acid TestingHuman Immunodeficiency Virus TestingLaboratory Diagnosis Of HivLinearityLinearity AssessmentViral Load Assays
No commercial viral load assay has yet been approved for use for measurement of human immunodeficiency virus type 2 (HIV-2) RNA levels in plasma. We assessed the performance of the NucliSens EasyQ (version 1.1) assay (EasyQ; bioMérieux, Boxtel, The Netherlands) to quantify HIV-2 viremia. A viral stock was prepared from an HIV-2 (subtype A)-infected patient. Culture supernatant was subjected to viral particle counting by electron microscopy. Serial dilutions of the viral stock were made in HIV-negative plasma and were used to test EasyQ for its sensitivity, linearity, and reproducibility. RNA was quantified by the NucliSens EasyQ (version 1.1) assay. Plasma samples from 75 HIV-2-infected patients were further tested. EasyQ was able to quantify HIV-2 RNA in a reproducible manner. Overall, estimates of the number of HIV-2 RNA copies/ml obtained with EasyQ were lower than those obtained by electron microscopy; however, the differences were always less than 0.7 log (mean, 0.55 +/- 0.19 log(10)). The assay showed good linearity (r(2) = 0.964; P < 0.0001). The agreement between both measures was assessed by use of a Bland-Altman plot; the narrow limits (0.158 to 0.952), defined as the mean difference +/- 2 standard deviations, indicated good agreement. The reproducibility was also good, since the between-run coefficients of variation were 1.49, 3.60, and 12.25% for samples containing 6.30, 4.30, and 2.30 log(10) HIV-2 RNA copies/ml, respectively. HIV-2 RNA was detected in 34 of 75 (45%) plasma specimens (mean, 2.72 log RNA copies/ml; range, 1.74 to 4.11 log RNA copies/ml); the rest of the specimens were considered to have undetectable viremia. A negative correlation was found between the number of HIV-2 RNA copies/ml and CD4 counts. In summary, EasyQ was shown to be reliable for the measurement of plasma HIV-2 subtype A RNA levels and may be a feasible tool for routine clinical monitoring of HIV-2 subtype A-infected patients.
23
Reduced Rate of Disease Development After HIV-2 Infection as Compared to HIV-1
Richard Marlink, Phyllis J. Kanki, Ibou Thior et al. · Science · 1994 · 626 citations
Stephen J. Popper, Abdoulaye Dieng Sarr, Karin Travers et al. · The Journal of Infectious Diseases · 1999 · 245 citations · Full text
Zhiwei Chen, A Luckay, Donald L. Sodora et al. · Journal of Virology · 1997 · 221 citations · Full text