Effects on perceived air quality and symptoms of exposure to microbially produced metabolites and compounds emitted from damp building materials

37

Citations

40

References

2008

Year

Abstract

Emissions from building materials caused by dampness and microbial growth may be involved in indoor air health problems. This study showed that exposure to high levels of VOC emitted from damp building materials and a mixture of mold may cause perceived poor air quality. It also indicated that stimulation of chemical warning systems (the nasal chemosensory part of the trigeminal system and the olfactory system) may enhance skin symptoms.