Automated quantification of coronary plaque with computed tomography: comparison with intravascular ultrasound using a dedicated registration algorithm for fusion-based quantification

Mark J. Boogers, Alexander Broersen, J.E. van Velzen, Fleur R. de Graaf, Heba M. El-Naggar, Pieter Kitslaar, Jouke Dijkstra, Victoria Delgado, Eric Boersma, Albert de Roos,

European Heart Journal · 2012 · 229 citations · 23 references

DOIFull text

Open access

Concepts

Abstract

AIMS: Previous studies have used semi-automated approaches for coronary plaque quantification on multi-detector row computed tomography (CT), while an automated quantitative approach using a dedicated registration algorithm is currently lacking. Accordingly, the study aimed to demonstrate the feasibility and accuracy of automated coronary plaque quantification on cardiac CT using dedicated software with a novel 3D coregistration algorithm of CT and intravascular ultrasound (IVUS) data sets. METHODS AND RESULTS: Patients who had undergone CT and IVUS were enrolled. Automated lumen and vessel wall contour detection was performed for both imaging modalities. Dedicated automated quantitative software (QCT) with a unique registration algorithm was used to fuse a complete IVUS run with a CT angiography volume using true anatomical markers. At the level of the minimal lumen area (MLA), percentage lumen area stenosis, plaque burden, and degree of remodelling were obtained on CT. Additionally, mean plaque burden was assessed for the whole coronary plaque. At the identical level within the coronary artery, the same variables were derived from IVUS. Fifty-one patients (40 men, 58 ± 11 years, 103 coronary arteries) with 146 lesions were evaluated. Quantitative computed tomography and IVUS showed good correlation for MLA (n = 146, r = 0.75, P < 0.001). At the level of the MLA, both techniques were well-correlated for lumen area stenosis (n = 146, r = 0.79, P < 0.001) and plaque burden (n = 146, r = 0.70, P < 0.001). Mean plaque burden (n = 146, r = 0.64, P < 0.001) and remodelling index (n = 146, r = 0.56, P < 0.001) showed significant correlations between QCT and IVUS. CONCLUSION: Automated quantification of coronary plaque on CT is feasible using dedicated quantitative software with a novel 3D registration algorithm.

References

23

ACC/AHA guidelines for coronary angiography11“ACC/AHA Guidelines for Coronary Angiography” was approved by the American College of Cardiology Board of Trustees in October 1998 and by the American Heart Association Science Advisory and Coordinating Committee in December 1998.22When citing this document, the American College of Cardiology and the American Heart Association request that the following format be used: Scanlon PJ, Faxon DP, Audet AM, Carabello B, Dehmer GJ, Eagle KA, Legako RD, Leon DF, Murray JA, Nissen SD, Pepine CJ, Watson RM. ACC/AHA guidelines for coronary angiography: a report of the American College of Cardiology/American Heart Association Task Force on Practice Guidelines (Committee on Coronary Angiography). J Am Coll Cardiol1999;33:1756–82433This document is available on the websites of the ACC (www.acc.org) and the AHA (www.americanheart.org). Reprints of this document (the complete guidelines) are available for $5 each by calling 800-253-4636 (US only) or writing the American College of Cardiology, Educational Services, 9111 Old Georgetown Road, Bethesda, MD 20814-1699. Ask for reprint No. 71-0164. To obtain a reprint of the shorter version (executive summary and summary of recommendations) published in the May 4, 1999, issue of Circulation, ask for reprint No. 71-0163. To purchase additional reprints (specify version and reprint number): up to 999 copies, call 800-611-6083 (US only) or fax 413-665-2671; 1000 or more copies, call 214-706-1466, fax 214-691-6342, or e-mail pubauth@heart.org

Patrick J. Scanlon, David P. Faxon, Anne-Marie Audet et al. · Journal of the American College of Cardiology · 1999 · 1.1K citations

, , +10