Concepedia

Publication | Closed Access

Comparison of three techniques for internal jugular vein cannulation in infants

164

Citations

18

References

2000

Year

Abstract

Central venous cannulation allows accurate monitoring of right atrial pressure and infusion of drugs during the anaesthetic management of infants undergoing cardiopulmonary bypass. In this prospective, randomized study, we compared the success and speed of cannulation of the internal jugular vein in 45 infants weighing less than 10 kg using three modes of identification: auditory signals from internal ultrasound (SmartNeedle, SM), external ultrasound imaging (Imaging Method, IM) and the traditional palpation of the carotid pulsation and other landmarks (Landmarks Method, LM). The cannulation time, number of attempts with LM and SM techniques were greater than those with IM technique. The incidence of carotid artery puncture and the success rate were not significantly different among the three groups. In infants, a method based on visual ultrasound identification (IM) of the internal jugular vein is more precise and efficient than methods based on auditory (SM) and tactile perception (LM).

References

YearCitations

Page 1