Medical Engineering & Physics · 2007 · 233 citations · 18 references
MedicinePhysical MedicineRehabilitation MedicineAssistive TechnologyMovement AnalysisSensorsGait AnalysisJoint Motion AnalysisMotion CaptureMovement KinematicsUpper Limb BiomechanicsUpper Limb RehabilitationInertial Measurement UnitsInertial SensingInertial SensorsUpper Limb Motion AnalysisWearable Sensors
This paper presents a new human motion tracking system using two wearable inertial sensors that are placed near the wrist and elbow joints of the upper limb. Each inertial sensor consists of a tri-axial accelerometer, a tri-axial gyroscope and a tri-axial magnetometer. The turning rates of the gyroscope were utilised for localising the wrist and elbow joints on the assumption that the two upper limb segment lengths are known a priori. To determine the translation and rotation of the shoulder joint, an equality-constrained optimisation technique is adopted to find an optimal solution, incorporating measurements from the tri-axial accelerometer and gyroscope. Experimental results demonstrate that this new system, compared to an optical motion tracker, has RMS position errors that are normally less than 0.01 m, and RMS angle errors that are 2.5-4.8 degrees .
18
Introduction to robotics: Mechanics and control
M.G. Rodd · Automatica · 1987 · 1.5K citations
Engineering, Mechanical Engineering, Robotics Engineering +10
Bijan Najafi, Kamiar Aminian, Anisoara Paraschiv-Ionescu et al. · IEEE Transactions on Biomedical Engineering · 2003 · 766 citations · Full text
Inertial sensor technology trends
N. Barbour, G. Schmidt · IEEE Sensors Journal · 2001 · 578 citations