IEEE Transactions on Electromagnetic Compatibility · 2008 · 38 citations · 9 references
EngineeringBioengineeringBiomedical EngineeringAntennasBiomedical ImagingMicrowave EngineeringElectromagnetic MethodsMicrowave MeasurementsElectric Field SensingElectromagnetic ImagingElectromagnetic InterferenceMicrowave Imaging
This paper presents two methods that accurately estimate the specific absorption rate (SAR) distribution and spatial averaged SAR in a phantom exposed to electromagnetic waves from a wireless device. These methods theoretically estimate the SAR value from a 2D scanned electric field (e-field) by basically applying the equivalence theorem. The validity of the proposed methods is investigated based on calculated and measured results. The estimated spatial averaged SAR over a 1-g or 10-g mass shows a difference of less than a few percent compared to the original SAR value. Furthermore, the proposed methods have the potential to measure the 3D SAR distribution in several tens of seconds or a few minutes when used in combination with a 2D probe array.
9