AFRICAN JOURNAL OF BIOTECHNOLOGY · 2007 · 43 citations · 14 references
EngineeringEnvironmental EngineeringEnvironmental SciencesReaction EngineeringWastewater TreatmentWater TreatmentHeavy Metal ContaminationHeavy Metal RemediationHeavy Metal RemovalIndustrial Effluent TreatmentIndustrial Wastewater TreatmentWastewater ManagementHydrogen Peroxide TreatmentMetal RemediationMetal RemovalPh Effects On Metal RemovalPh OptimaPre-treatmentWastewater Treatment For Heavy MetalsWastewater Treatment Processes
The batch removal of heavy metals lead (Pb), zinc (Zn) and copper (Cu) from industrial wastewater effluent under different experimental conditions using hydrogen peroxide was investigated. Experimental results indicated that at pH 6.5, pre-treatment analysis gave the following values: Pb 57.63 mg/l, Zn 18.9 mg/l and Cu 13.9 mg/l. Removal of heavy metals was optimum at pH 7.6, a temperature of 30oC, 1.5% hydrogen peroxide concentration and 60 min holding time, reducing the amounts of Pb, Zn and Cu by 83.5, 85.5 and 82.23%, respectively.
14
Hydrogen Peroxide Catalytic Oxidation of Refractory Organics in Municipal Waste Waters
Dolloff F. Bishop, Gerry Stern, Marvin Fleischman et al. · Industrial & Engineering Chemistry Process Design and Development · 1968 · 202 citations
Natural Sciences, Chemical Engineering, Environmental Engineering +7
Removal of heavy metals from aqueous solution by apple residues
Sungho Lee, Chong Hun Jung, Hongsuk Chung et al. · Process Biochemistry · 1998 · 148 citations