Journal of Applied Physiology · 2010 · 21 citations · 31 references
Health ProfessionsPhysiologyRadiologyDiagnostic ImagingPulmonary Function TestingVentilationForced Expiratory VolumeForced Vital CapacityLung Compliance AssessmentPulmonary Function AssessmentPulmonary ImagingPulmonary MechanicsEmphysema QuantificationLung Function TestingLung Function-related Functional CapacityLung Volume QuantificationRegional CorrelationRegional Lung Function AssessmentRegional Lung VentilationTotal Lung Capacity
Regional and global relationships of lung function and structure were studied using hyperpolarized ³He MRI in a rat elastase-induced model of emphysema (n = 4) and healthy controls (n = 5). Fractional ventilation (r) and apparent diffusion coefficient (ADC) of ³He were measured at a submillimeter planar resolution in ventral, middle, and dorsal slices 6 mo after model induction. Pulmonary function testing (PFT) was performed before MRI to yield forced expiratory volume in 50 ms (FEV₅₀), airway resistance (R(I)), and dynamic compliance (C(dyn)). Cutoff threshold values of ventilation and diffusion, r* and ADC*, were computed corresponding to 80% population of pixels falling above or below each threshold value, respectively. For correlation analysis, r* was compared with FEV₅₀/functional residual capacity (FRC), R(I) and C(dyn), whereas ADC* was compared with FEV₅₀/FRC, total lung capacity (TLC), and C(dyn). Regional correlation of r and ADC was evaluated by dividing each of the three lung slices into four quadrants. C(dyn) was significantly larger in elastase rats (0.92 ± 0.16 vs. 0.61 ± 0.12 ml/cmH₂O). The difference of R(I) and FEV₅₀ was insignificant between the two groups. The r* of healthy rats was significantly larger than the elastase group (0.42 ± 0.03 vs. 0.28 ± 0.06), whereas ADC* was significantly smaller in healthy animals (0.27 ± 0.04 vs. 0.36 ± 0.01 cm²/s). No systematic difference in these quantities was observed between the three lung slices. A significant 33% increase in ADC* and a significant 31% decline in r* for elastase rats was observed compared with a significant 51% increase in C(dyn) and a nonsignificant 26% decline in FEV₅₀/FRC. Correlation of imaging and PFT metrics revealed that r and ADC divide the rats into two separate clusters in the sample space.
31
Standards for the Diagnosis and Care of Patients with Chronic Obstructive Pulmonary Disease
Bartolomé R. Celli, Gordon L. Snider, John E. Heffner et al. · 1995 · 3.5K citations
Medicine, Surgery, Exercise Testing +16
Spin-exchange optical pumping of noble-gas nuclei
Thad Walker, W. Happer · Reviews of Modern Physics · 1997 · 1.4K citations
Chronic Obstructive Pulmonary Disease
Peter J. Barnes · New England Journal of Medicine · 2000 · 1.1K citations