Medicina oral, patología oral y cirugía bucal · 2013 · 29 citations · 22 references
DentistryOral RadiologyRadiologyDental RadiologyDiagnostic ImagingMaxillofacial ImagingCephalometric AnalysisCephalometric ImagingCephalometric RadiographyCone Beam Computed Tomography InterpretationMaxillofacial RadiographyThree-dimensional Cephalometric AnalysisCephalometric AnglesCephalometric Angular MeasurementsCephalometric Mandibular AssessmentCorrelationDental Relationship AssessmentMaxillofacial Skeletal AssessmentThree-dimensional Dental AssessmentWits Appraisal
OBJECTIVES: To analyse the ANB and Wits values and to study correlations between those two measurements and other measurements in diagnosing the anteroposterior maxilo-mandibular relationship with CBCT. STUDY DESIGN: Ninety patients who had previously a CBCT (i-CAT®) as a diagnostic register were selected. A 3D cephalometry was designed using one software package, InVivo5®. This cephalometry included 3 planes of reference, 3 angle measurements and 1 linear measurement. The means and standard deviations of the mean of each measurement were assessed. After that, a Pearson's correlation coefficient has been performed to analyse the significance of each relationship. RESULTS: When classifying the sample according to the anteroposterior relationship, the values obtained of ANB (Class I: 53%; Class II: 37%; Class III: 10%) and Wits (Class I: 35%; Class II: 56%; Class III: 9%) did not coincide, except for the Class III group. However, of the patients classified differently (Class I and Class II patients) by ANB and Wits, a high percentage of individuals (n=22; 49%), had a mesofacial pattern with a mandibular plane angle within normal values. A correlation has been found between ANB and Wits (r=0,262), occlusal plane angle and ANB (r=0,426), and mandibular plane angle and Wits (r=0,242). No correlation was found between either Wits or ANB in relation with the age of the individuals. CONCLUSIONS: ANB and Wits must be included in 3D cephalometric analyses as both are necessary to undertake a more accurate diagnosis of the maxillo-mandibular relationship of the patients.
22
Accuracy of three-dimensional measurements using cone-beam CT
HM Pinsky, S Dyda, RW Pinsky et al. · Dentomaxillofacial Radiology · 2006 · 344 citations
Danielle R. Periago, William C. Scarfe, Mazyar Moshiri et al. · The Angle Orthodontist · 2007 · 320 citations · Full text
Comparison of cone beam computed tomography imaging with physical measures
SA Stratemann, JC Huang, K. Maki et al. · Dentomaxillofacial Radiology · 2008 · 275 citations
Application of the “Wits” appraisal
Alex Jacobson · American Journal of Orthodontics · 1976 · 208 citations
Nursing, Psychology, Persuasion +5