Measurement Science and Technology · 2004 · 46 citations · 4 references
EngineeringEarth SciencesElectrical EngineeringElectromagnetismInstrumentationSensorsCurrent Measurement InstrumentsMagnetic FieldsMagnetic SensorsFluxgate MagnetometersFluxgate MagnetometryMagnetic Field IntensityMagnetic Field MeasurementsMagnetometer InstrumentationMagnetometer MeasurementsMagnetometersSensitivity
A new variometer is developed comprising a fast-response scalar optically pumped potassium magnetometer inside a rotating magnetic field created by a two-dimensional coil system mounted on a quartz frame. The variometer measures three components of the Earth's field: the total field intensity and two transverse components. The theoretically predicted accuracy of the field component measurement is not worse than 0.1 nT. The noise-limited sensitivity measured in a quiet magnetic field has been proved to be not worse than 25 pT rms at 0.2 s and 30 pT rms at 1 min; comparison with a proton vector magnetometer and a fluxgate magnetometer shows 1.5 nT p–t–p daily deviation.
4
Scalar calibration of vector magnetometers
José M.G. Merayo, Peter Bräuer, F. Primdahl et al. · Measurement Science and Technology · 2000 · 238 citations
On the calibration of a vectorial 4He pumped magnetometer
O. Gravrand, A. Khokhlov, Jean‐Louis Le Mouël et al. · Earth Planets and Space · 2014 · 68 citations · Full text