DC corona discharge from a wire particle floated with a microgap in parallel plate electrodes

14

Citations

11

References

2006

Year

Abstract

Conductive particles existing in a high-voltage system could deteriorate the system performance owing to an electric discharge via the particles. In case when the particles exist in a dc high-voltage electrode system, the location of the particle would inevitably affect the discharge aspect. A corona-onset and breakdown voltage from a metallic wire particle were measured in detail. The wire particle has a length ranging from 6 to 12 mm, and a diameter of 0.25 mm. It was fixed between a parallel plate electrode with a spacing of 20 or 30 mm. When the particle was close to the negative electrode, a corona discharge occurred stably, and the corona-onset voltage was increased as the gap length between the negative electrode, and the positive end of the particle increased up to 0.8 mm. In contrast, when the particle was close to the positive electrode, the breakdown always occurred without preceding the corona discharge. At the middle region between the electrodes, the corona onset occurred at almost constant voltage