Journal of Clinical Oncology · 2010 · 198 citations · 41 references
MedicineOncologyRadiologyBiomedical ImagingDiagnostic ImagingDiagnostic RadiologyBaseline Cardiac EvaluationBreast Cancer ImagingCancer Therapy-related CardiotoxicityCardiac ImagingCardiovascular ImagingLeft Ventricular Function AssessmentCardiac Monitoring During Cancer TherapyCorrelation With EchocardiographyEchocardiographic Image AcquisitionEchocardiographic QuantificationMultimodality Cardiac ImagingTwo-dimensional EchocardiographyVentricular Diastolic FunctionVentricular Ejection Fraction Assessment
PURPOSE: In patients with breast cancer, the administration of doxorubicin and trastuzumab is associated with an increased risk of cardiotoxicity. Although multiple-gated acquisition (MUGA) scans and two-dimensional transthoracic echocardiography (TTE) are conventional methods for baseline and serial assessment of left ventricular ejection fraction (LVEF) in these patients, little is known about the use of real-time three-dimensional TTE (RT3D TTE) in this clinical setting. The aim of this study was to assess the accuracy of MUGA, 2D TTE, and RT3D TTE for determining LVEF in comparison to cardiac magnetic resonance imaging (CMR). METHODS: Between 2007 and 2009 inclusive, 50 female patients with human epidermal growth factor receptor 2-positive breast cancer received adjuvant trastuzumab after doxorubicin. Serial MUGA, 2D TTE, RT3D TTE, and CMR were performed at baseline, 6, and 12 months after the initiation of trastuzumab. RESULTS: A comparison of left ventricular end diastolic volume (LVEDV) demonstrated a modest correlation between 2D TTE and CMR (r = 0.64 at baseline; r = 0.69 at 12 months, respectively). A comparison of LVEDV between RT3D TTE and CMR demonstrated a stronger correlation (r = 0.87 at baseline; r = 0.95 at 12 months, respectively). Although 2D TTE demonstrated a weak correlation with CMR for LVEF assessment (r = 0.31 at baseline, r = 0.42 at 12 months, respectively), both RT3D TTE and MUGA showed a strong correlation when compared with CMR (r = 0.91 at baseline; r = 0.90 at 12 months, respectively). CONCLUSION: As compared with conventional MUGA, RT3D TTE is a feasible, accurate, and reproducible alternate imaging modality for the serial monitoring of LVEF in patients with breast cancer.
41
Roberto M. Lang, Michelle Bierig, Richard B. Devereux et al. · Journal of the American Society of Echocardiography · 2005 · 11.3K citations
Trastuzumab plus Adjuvant Chemotherapy for Operable HER2-Positive Breast Cancer
Edward H. Romond, Edith A. Perez, John Bryant et al. · New England Journal of Medicine · 2005 · 5.4K citations · Full text
Medicine, Oncology, Pharmacotherapy +17
Trastuzumab after Adjuvant Chemotherapy in HER2-Positive Breast Cancer
Martine Piccart, Marion Procter, Brian Leyland‐Jones et al. · New England Journal of Medicine · 2005 · 5.1K citations · Full text
Medicine, Oncology, Pharmacology +16