Journal of Cardiovascular Magnetic Resonance · 2012 · 561 citations · 15 references
MedicineCardiologyRadiologyClinical CardiologyDiagnostic ImagingDiagnostic RadiologyCardiac ImagingCardiac Nuclear ImagingCardiovascular ImagingMagnetic Resonance ImagingMedical ImagingCardiac Ischemia ImagingDelayed Enhancement ImagingLate Gadolinium Enhancement ImagingMultimodality Cardiac ImagingMyocardial Infarction ImagingMyocardial Infarction LocalizationRepeat Imaging StrategyT2-weighted Imaging
BACKGROUND: Myocardial infarction (MI) documented by late gadolinium enhancement (LGE) has clinical and prognostic importance, but its detection is sometimes compromised by poor contrast between blood and MI. MultiContrast Delayed Enhancement (MCODE) is a technique that helps discriminate subendocardial MI from blood pool by simultaneously providing a T2-weighted image with a PSIR (phase sensitive inversion recovery) LGE image. In this clinical validation study, our goal was to prospectively compare standard LGE imaging to MCODE in the detection of MI. METHODS: Imaging was performed on a 1.5 T scanner on patients referred for CMR including a LGE study. Prospective comparisons between MCODE and standard PSIR LGE imaging were done by targeted, repeat imaging of slice locations. Clinical data were used to determine MI status. Images at each of multiple time points were read on separate days and categorized as to whether or not MI was present and whether an infarction was transmural or subendocardial. The extent of infarction was scored on a sector-by-sector basis. RESULTS: Seventy-three patients were imaged with the specified protocol. The majority were referred for vasodilator perfusion exams and viability assessment (37 ischemia assessment, 12 acute MI, 10 chronic MI, 12 other diagnoses). Forty-six patients had a final diagnosis of MI (30 subendocardial and 16 transmural). MCODE had similar specificity compared to LGE at all time points but demonstrated better sensitivity compared to LGE performed early and immediately before and after the MCODE (p = 0.008 and 0.02 respectively). Conventional LGE only missed cases of subendocardial MI. Both LGE and MCODE identified all transmural MI. Based on clinical determination of MI, MCODE had three false positive MI's; LGE had two false positive MI's including two of the three MCODE false positives. On a per sector basis, MCODE identified more infarcted sectors compared to LGE performed immediately prior to MCODE (p < 0.001). CONCLUSION: While both PSIR LGE and MCODE were good in identifying MI, MCODE demonstrated more subendocardial MI's than LGE and identified a larger number of infarcted sectors. The simultaneous acquisition of T1 and T2-weighted images improved differentiation of blood pool from enhanced subendocardial MI.
15
An Improved MR Imaging Technique for the Visualization of Myocardial Infarction
Orlando P. Simonetti, Raymond J. Kim, David S. Fieno et al. · Radiology · 2001 · 1.4K citations
Medicine, Cardiology, Radiology +16
Raymond Y. Kwong, Anna Chan, Kenneth A. Brown et al. · Circulation · 2006 · 745 citations · Full text
Selçuk Adabağ, Barry J. Maron, Evan Appelbaum et al. · Journal of the American College of Cardiology · 2008 · 670 citations
Medicine, Cardiology, Radiology +13