EngineeringBiomedical EngineeringElectrical EngineeringEnergy SystemsPower ElectronicsWireless CommunicationsElectromagnetic PowerImplant TechnologyImplantable Biomedical DevicesImplantable MicrosystemsMaximum Power TransferWireless Power TransferBiomedical ImplantsBiomedical Wireless Power TransferInductive Power TransferPower Transfer EfficiencyProof Of Concept PrototypesResonant Energy TransferResonant Power TransferWireless Power Transfer For Implants
Resonance‑based wireless power delivery efficiently transfers power over relatively long distances and, unlike two‑coil systems, its efficiency is less sensitive to distance variations. The study aims to optimize a four‑coil energy transfer system for maximum efficiency at a specified operating distance. The authors employ a four‑coil resonant system with high‑Q coils to compensate low coupling, outline design steps, and build a prototype to achieve efficient power transfer. Analysis and prototype experiments show that the optimized four‑coil system achieves over 80 % efficiency at 10–20 mm, surpassing the ~40 % efficiency of conventional two‑coil links.
Resonance-based wireless power delivery is an efficient technique to transfer power over a relatively long distance. This technique typically uses four coils as opposed to two coils used in conventional inductive links. In the four-coil system, the adverse effects of a low coupling coefficient between primary and secondary coils are compensated by using high-quality (Q) factor coils, and the efficiency of the system is improved. Unlike its two-coil counterpart, the efficiency profile of the power transfer is not a monotonically decreasing function of the operating distance and is less sensitive to changes in the distance between the primary and secondary coils. A four-coil energy transfer system can be optimized to provide maximum efficiency at a given operating distance. We have analyzed the four-coil energy transfer systems and outlined the effect of design parameters on power-transfer efficiency. Design steps to obtain the efficient power-transfer system are presented and a design example is provided. A proof-of-concept prototype system is implemented and confirms the validity of the proposed analysis and design techniques. In the prototype system, for a power-link frequency of 700 kHz and a coil distance range of 10 to 20 mm, using a 22-mm diameter implantable coil resonance-based system shows a power-transfer efficiency of more than 80% with an enhanced operating range compared to ~40% efficiency achieved by a conventional two-coil system.
39
Wireless Power Transfer via Strongly Coupled Magnetic Resonances
André Kurs, Aristeidis Karalis, Robert Moffatt et al. · Science · 2007 · 5.5K citations · Full text
H. A. Haus, Wenxin Huang · Proceedings of the IEEE · 1991 · 949 citations