2006 IEEE Power Engineering Society General Meeting · 2006 · 19 citations · 0 references
EngineeringMechanical EngineeringNuclear EngineeringAir ConditioningHeat TransferWater ConservationEnergy ConversionEvaporative CoolingMachine CoolingPower Plant OperationPower Plant Performance AnalysisRefrigeration SystemsAuxiliary Power SystemsCooling System DesignGenerator CoolingGenerator DesignGenerator EfficiencyMachine Cooling SystemsPower FactorThermal Efficiency Optimization
Olkiluoto 3 will have a rated capability of 1992 MVA at 0.90 power factor, giving it the highest rating ever attained by a turbogenerator. Although the machine is highly efficient (expected generator efficiency is 99% at rated output), the generator losses are expected to exceed 20 MW under some system conditions. The generator must be cooled using advanced generator cooling techniques and state-of-the-art gas and water cooling auxiliary systems. The challenges were overcome by engineers working closely with generator designers to optimize cooling circuits and to develop modern hydrogen gas and stator water systems for modern nuclear power plant operation.