Computing in Cardiology · 2011 · 28 citations · 6 references
EngineeringBiophysicsPhysiologyBioenergeticsBioinstrumentationBiomedical Signal ProcessingBiomedical Signal ModelingCellular RespirationPhysiological Signal AcquisitionRespiration PhysiologyRespiratory PhysiologyRespiratory Signal AnalysisPhotoplethysmogram Signal ProcessingPhotoplethysmographyRespiratory Rate Estimation
A method for respiratory signal estimation from the pulse photoplethysmographic (PPG) signal is presented. The method is based on combination of three parameters present in this signal: pulse rate variability, pulse amplitude variability and pulse width variability. Evaluation is performed over a database containing electrocardiographic (ECG), PPG and respiratory signals simultaneously recorded in 17 subjects during a tilt table test, obtaining a respiratory rate estimation error of −0.26±7.30% (−2.11±14.49 mHz). These results are comparable or outperform those obtained from other methods which involve the ECG, so it is possible to have reliable respiration estimates from just the PPG.
6
Pulse rate variability is not a surrogate for heart rate variability
Isabelle Constant, Dominique Laude, I. Murat et al. · Clinical Science · 1999 · 149 citations
Medicine, Cardiology, Physiology +17