MedicineOncologyRadiation OncologyRadiation PhysicsRadiation TransportTreatment PlanningMonte Carlo DosimetryMonte Carlo Radiation TransportRadiation TherapyRadiation Treatment PlanningStereotactic RadiosurgeryTreatment Planning Dose CalculationBremsstrahlungMonte Carlo Dose ModelingMonte Carlo Dose SimulationRadiotherapy Dose PlanningRussian RouletteStereotactic Radiotherapy PlanningStereotactic Treatment PlanningSuperposition Algorithms
Accurate dose calculation is essential to advanced stereotactic radiosurgery (SRS) and stereotactic radiotherapy (SRT) especially for treatment planning involving heterogeneous patient anatomy. This paper describes the implementation of a fast Monte Carlo dose calculation algorithm in SRS/SRT treatment planning for the CyberKnife® SRS/SRT system. A superposition Monte Carlo algorithm is developed for this application. Photon mean free paths and interaction types for different materials and energies as well as the tracks of secondary electrons are pre-simulated using the MCSIM system. Photon interaction forcing and splitting are applied to the source photons in the patient calculation and the pre-simulated electron tracks are repeated with proper corrections based on the tissue density and electron stopping powers. Electron energy is deposited along the tracks and accumulated in the simulation geometry. Scattered and bremsstrahlung photons are transported, after applying the Russian roulette technique, in the same way as the primary photons. Dose calculations are compared with full Monte Carlo simulations performed using EGS4/MCSIM and the CyberKnife treatment planning system (TPS) for lung, head & neck and liver treatments. Comparisons with full Monte Carlo simulations show excellent agreement (within 0.5%). More than 10% differences in the target dose are found between Monte Carlo simulations and the CyberKnife TPS for SRS/SRT lung treatment while negligible differences are shown in head and neck and liver for the cases investigated. The calculation time using our superposition Monte Carlo algorithm is reduced up to 62 times (46 times on average for 10 typical clinical cases) compared to full Monte Carlo simulations. SRS/SRT dose distributions calculated by simple dose algorithms may be significantly overestimated for small lung target volumes, which can be improved by accurate Monte Carlo dose calculations.
13
BEAM: A Monte Carlo code to simulate radiotherapy treatment units
D. W. O. Rogers, Bruce Faddegon, G Ding et al. · Medical Physics · 1995 · 1.4K citations
Clinical implementation of a Monte Carlo treatment planning system
E Mok, Ajay Kapur, Todd Pawlicki et al. · Medical Physics · 1999 · 297 citations
Monte Carlo treatment planning for photon and electron beams
N. Reynaert, S.C. van der Marck, Dennis R. Schaart et al. · Radiation Physics and Chemistry · 2006 · 156 citations
Accurate characterization of Monte Carlo calculated electron beams for radiotherapy
C. M., Bruce Faddegon, D. W. O. Rogers et al. · Medical Physics · 1997 · 149 citations