Lara D. Veeken · 2010 · 60 citations · 35 references
NursingOrthopaedic SurgeryOrthopedic SurgeryFunctional AssessmentHealth AssessmentOrthopedicsHand Function AssessmentLower Extremity Function AssessmentOsteoarthritisOutcome AssessmentPatient-reported Outcome MeasuresUpper Extremity Function AssessmentConstruct ValidityHand Function QuestionnairesInternal Consistency ReliabilityItem-total CorrelationOsteoarthritis Of The HandPatient-reported Hand FunctionPatient-reported Outcome MeasurementTest-retest Reliability
OBJECTIVES: Concurrent evaluation of data quality, internal consistency, test-retest reliability and validity of two patient-reported outcome measures (PROMs) for measuring functional impairment in hand OA (HOA); the Australian/Canadian Osteoarthritis Hand Index (AUSCAN; 15 items) and the Functional Index of HOA (FIHOA; 10 items). METHODS: Patients from an HOA cohort [n=128, mean age 68.6 (s.d. 5.8) years, 91% women] completed PROMs and performance measures during routine follow-up. One week later, a subsample (n=40) reporting no change on an HOA-specific transition question contributed with test-retest data. RESULTS: Both instruments had satisfactory levels of data quality, internal consistency, test-retest reliability and construct validity. The AUSCAN performed slightly better than the FIHOA relating to levels of missing data (0 vs 5%), floor effects, principal component analysis loadings (0.62-0.83 vs 0.52-0.83), item-total correlation (0.77-0.91 vs 0.45-0.76) and Cronbach's α (0.94-0.96 vs 0.90), respectively. AUSCAN items had slightly lower test-retest κ-values (0.29-0.77 vs FIHOA 0.41-0.77) and AUSCAN scales lower intra-class correlations (0.80-0.92 vs FIHOA 0.94). Correlations between the two instruments ranged from 0.58 to 0.88 for the AUSCAN scales of stiffness and physical function, respectively. AUSCAN physical function scale was generally slightly strongly correlated with the other PROMS and performance measures. CONCLUSION: The AUSCAN and the FIHOA are reliable and valid instruments suitable for measuring physical functioning in HOA. The FIHOA had higher test-retest reliability and is shorter, but the AUSCAN performed slightly better concerning data quality and construct validity.
35
Colin Goodall, Ian T. Jolliffe · Technometrics · 1988 · 8.7K citations
Measurement of patient outcome in arthritis
James F. Fries, Patricia W. Spitz, R. Guy Kraines et al. · Arthritis & Rheumatism · 1980 · 4.4K citations
Reliability and validity of grip and pinch strength evaluations
Virgil Mathiowetz, Karen C. Weber, Gloria Volland et al. · The Journal Of Hand Surgery · 1984 · 1.9K citations