Load Dependent Dead-Times Controller Based on Minimized Duty Cycle Technique for DC-DC Buck Converters
15
Citations
8
References
2007
Year
Unknown Venue
Low-power ElectronicsElectrical EngineeringChip SizeEngineeringPower IcDead-times ControllerPower Electronics ConverterComputer EngineeringDead TimesDc-dc Buck ConvertersElectric Power ConversionPower Electronic SystemsPower InverterDistributed Control SystemPower ElectronicsPower-aware Design
A load dependent current-mode dead-times controller based on minimized duty cycle technique for DC-DC synchronous buck converters is proposed to achieve near-optimum dead times. This dead-times controller can dynamically adjust the dead times according to the variations of load. Experimental results demonstrate the validity of proposed circuit and power efficiency is raised about 1~5%. The chip size is 3.2mm <sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">2</sup> in 0.35 μm CMOS process.