Applied Optics · 1998 · 10 citations · 2 references
EngineeringWater Resources ManagementFluid DynamicsHydraulicsMetrologyFlow MeasurementFlow MetrologyFlow SensorsInterferometryOptical FlowPipeline SystemsDiffraction-limited PerformanceFiber CouplingFiber-optic Flow SensorsFlow Measurement DevicesFlow Measurement SystemsFlow Profile MeasurementOptical System AlignmentReal-time Processing
We used a near-diffraction-limited flow or light-wave-interaction pipe to produce a Sagnac-interferometer-based Fresnel drag fluid flowmeter capable of detecting extremely small flow rates. An optimized design of the pipe along with the use of a state-of-the-art Sagnac interferometer results in a minimum-detectable water flow rate of 2.4 nl/s [1 drop/(5 h)]. The flowmeter's capability of measuring the water consumption by a small plant in real time has been demonstrated. We then designed an automated alignment system that finds and maintains the optimum fiber-coupling regime, which makes the applications of the Fresnel-drag-based flowmeters practical, especially if the length of the interaction pipe is long. Finally, we have applied the automatic alignment technique to an air flowmeter.
2