Ground Water · 1982 · 46 citations · 2 references
Natural ResourcesEarth SciencesHydrologyGroundwater HydrologyGroundwater ManagementWater Resources EngineeringAquifer CharacterizationAquifer FlowAquifer PropertiesGroundwater HydraulicsGroundwater ModelingUnconfined AquifersAquifer Parameter EstimationAquifer TestingGroundwater HeadGroundwater PiezometryHydraulic TestingOpen ObservationUnconfined Aquifer FlowUnconfined Aquifer Head
ABSTRACT Initial attempts to estimate unconfined aquifer parameters from a pumping test using an open observation borehole proved to be unsuccessful. However, when separate piezometers were installed along a vertical section, significant differences in ground‐water head were noted. These differences suggest that rather than providing an average ground‐water head, the open borehole provides a means of flow between the different elevations and therefore produces misleading results. The results for the separate piezometers are analysed using a numerical model, and reasonable values of the aquifer parameters are deduced.
2
Shlomo P. Neuman · Journal of Hydrology · 1980 · 113 citations