IEEE Transactions on Electromagnetic Compatibility · 1988 · 17 citations · 1 references
EngineeringElectrical EngineeringMaterials ScienceElectromagneticsElectromagnetismMicrowave EngineeringMicrowave MaterialsShielding DesignShielding MaterialsElectromagnetic Radiation EffectsElectromagnetic ShieldingShielded EnclosuresShieldingShielding Effectiveness AssessmentShielding Effectiveness EvaluationShielding EfficiencyShielding Fabrics
A combined experimental and theoretical evaluation of shielding effectiveness of metallized fabric enclosures against electromagnetic radiation in the frequency range 10 kHz-130 MHz is reported. The test object consisted of a small wooden frame covered with one of two types of DEVEX metallized fabric. The shielding effectiveness of each fabric was measured in terms of a transfer function for the given enclosure. Deliberate degradations made to the enclosure shield demonstrated the importance of having a well-controlled or 'tight' shield. A low-frequency calculational model allowed computation of the expected internal magnetic fields in the enclosure. The results of the experimental study compare favorably with the predictions of the model.< <ETX xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">></ETX>
1
R. W. Latham, K. S. H. Lee · Canadian Journal of Physics · 1968 · 13 citations