Inter-area oscillation damping with power system stabilizers and synchronized phasor measurements

Aaron F. Snyder, Nourédine Hadjsaïd, Didier Georges, Lamine Mili, A.G. Phadke, O. Faucon, S. Vitet

2002 · 66 citations · 8 references

DOIFull text

Open access

Concepts

TL;DR

Low‑frequency oscillations degrade maximum power transfer and system security, and power‑system stabilizers added to generator AVRs provide damping to mitigate these effects. The study proposes a novel controller modification that incorporates remote source information into the stabilizer feedback loop. The modified controller responds to changes from both local and remote sources, adjusting the stabilizer output accordingly. Simulation results show the enhanced controller rapidly reduces oscillations in a test power system.

Abstract

Low-frequency oscillations are detrimental to the goals of maximum power transfer and optimal power system security. A contemporary solution to this problem is the addition of power system stabilizers to the automatic voltage regulators on the generators in the power system. The damping provided by this additional stabilizer provides the means to reduce the inhibiting effects of the oscillations. A novel modification of this controller is the inclusion in the feedback loop of information from a remote source. In this manner, the controller acts on the changes from the local source and the remote source. As is demonstrated, this yields a controller capable of more rapidly diminishing the oscillations in a test power system.

References

8