The Laryngoscope · 2008 · 93 citations · 40 references
MedicineOtolaryngologyCochlear ImplantsImplant SurgeryOtologyCochlear AnatomyCochlear ImplantationImplant Treatment PlanningImplant-site ImagingSurgical ImplantationTemporal Bone SurgeryAutomated Drill Path OptimizationBasal Turn AnatomyBone-anchored Hearing ImplantationCochlear Implant Surgical PlanningFacial Implant SurgeryFacial Recess AnatomyFacial Recess ApproachImaging For Cochlear Implantation
Percutaneous cochlear implant surgery uses a single drill trajectory from the lateral mastoid cortex through the facial recess to the cochlea. The study aimed to clinically validate this percutaneous approach in patients scheduled for conventional cochlear implant surgery. In a prospective trial, patients received bone‑implanted anchors, preoperative CT scans, and computer‑planned paths, after which custom microstereotactic drill guides were mounted to direct a single drill through the facial recess to the cochlea under local anesthesia. All five ears achieved accurate trajectories, with mean distances from the drill midpoint to the facial nerve of 1.18 mm (manual) and 1.24 mm (automatic), and to the chorda tympani of 0.99 mm (manual) and 1.22 mm (automatic), demonstrating safe percutaneous access.
Percutaneous cochlear implant surgery consists of a single drill path from the lateral mastoid cortex to the cochlea via the facial recess. We sought to clinically validate this technique in patients undergoing traditional cochlear implant surgery.Prospective clinical trial.After institutional regulatory board-approved protocols, five ears were studied via the following steps. 1) In the clinic under local anesthesia, bone-implanted anchors were placed surrounding each mastoid. 2) Temporal-bone computed tomography (CT) scans were obtained. 3) On the CT scans, paths were planned from the lateral mastoid cortex, through the facial recess, to the basal turn of the cochlea both "manually" and "automatically" using computer software. 4) Customized microstereotactic frames were rapid-prototyped to serve as drill guides constraining the drill to follow the appropriate path. 5) During cochlear implant surgery, after drilling of the facial recess, drill guides were mounted on the bone-implanted anchors. 6) Accuracy of paths was assessed via intraoperative photodocumentation.All surgical paths successfully traversed the facial recess and hit the basal turn of the cochlea. Distance in millimeters (average +/- SD) from the midpoint of the drill to the facial nerve was 1.18 +/- 0.68 for the "manual" path and 1.24 +/- 0.44 mm for the "automatic" path and for the chorda tympani 0.986 +/- 0.48 for the "manual" path and 1.22 +/- 0.62 for the "automatic" path.Percutaneous cochlear implant access using customized drill guides based on preoperative CT scans and image-guided surgery technology can be safely accomplished.
40
Multi-modal volume registration by maximization of mutual information
William M. Wells, Paul Viola, Hideki Atsumi et al. · Medical Image Analysis · 1996 · 1.9K citations
Multi-modality image registration by maximization of mutual information
Frederik Maes, André Collignon, Dirk Vandermeulen et al. · 1996 · 804 citations