European Journal of Cardio-Thoracic Surgery · 2012 · 63 citations · 21 references
MedicineSurgeryCardiothoracic SurgeryImplant SurgerySurgical InstrumentationAortic SurgeryImplant MaterialsImplantable Biomedical DevicesSurgical Valve ReplacementTranscatheter Aortic Valve ReplacementTranscatheter Valve TherapyHigh-risk Surgical PatientsTactile FeedbackTactile Feedback InputValve Deployment TechniqueValve Prosthesis DesignValve-in-valve Therapy
OBJECTIVES: The ACURATE TA(™) Aortic Bioprosthesis and Delivery System (Symetis S.A., Ecublens, Switzerland) is a new transcatheter aortic valve designed for transapical implantation. The six-month results from the completed first-in-man study are reported. METHODS: The Symetis ACURATE TA(™) is composed of a porcine biological tissue valve attached to a self-expandable nitinol stent. It allows for anatomical orientation and facilitates intuitive implantation providing tactile feedback. Since November 2009, a total of 40 high-risk elderly patients have been treated. RESULTS: The mean age of enrolled patients was 83.2 ± 4.0; 60.0% were female, with a mean logistic EuroSCORE of 21.2 ± 10.8% and a mean Society of Thoracic Surgeons (STS) score of 9.0 ± 4.7%. All implants were delivered successfully in the intra-annular and subcoronary position. One patient was converted to conventional surgery due to coronary impingement (after valve-in-valve implantation). One additional patient received valve-in-valve treatment (SAPIEN THV TA(™)). Five patients expired within 30 days and two additional patients expired during the 6-month follow-up due to non-valve-related causes resulting in a mid-term survival rate of 82.5%. Two patients suffered a stroke and another three required new onset pacemaker implantation. The mean aortic gradient significantly improved and remained stable throughout the follow-up (baseline: 51.9 ± 14.3 mmHg, 30 days: 12.3 ± 5.1 mmHg, 6 months: 11.9 ± 5.8 mmHg). At the 6-month follow-up, 96.7% of patients demonstrated either none/trace or mild (1+/4) paravalvular leakage only. According to the Valve Academic Research Council the device's success rate was 92.5%, with a 30-day safety profile of 25%. CONCLUSIONS: At the 6-month follow-up, the ACURATE TA(™) device showed stable valve function with low rates of paravalvular leakages. The cohort of high-risk patients demonstrated good clinical outcomes and 6-month survival.
21
Transcatheter versus Surgical Aortic-Valve Replacement in High-Risk Patients
Craig R. Smith, Martin B. Leon, Michael J. Mack et al. · New England Journal of Medicine · 2011 · 6.3K citations · Full text
Medicine, Cardiology, Surgery +13
M.B. Leon, Nicolò Piazza, Eugenia Nikolsky et al. · European Heart Journal · 2011 · 1.2K citations · Full text
Medicine, Cardiology, Surgery +17
Eberhard Grube, Gerhard Schüler, Lutz Buellesfeld et al. · Journal of the American College of Cardiology · 2007 · 948 citations
Medicine, Cardiology, Surgery +16