EP Europace · 2013 · 34 citations · 5 references
MedicineRadiologySurgeryPatient SafetyRadiation ProtectionRadiation SafetyAblation TherapyOccupational Radiation ProtectionOccupational Radiation SafetyPatient Radiation SafetyRadiation Hazard AssessmentRadiation Risk AssessmentDigital FluoroscopyDisposable GlovesLead Glass ShieldingRadiation Exposure ManagementRadiation Safety In FluoroscopyX-ray Equipment SafetyX-ray Exposure AssessmentX-ray Safety
The purpose of the survey was to evaluate physician's and authorities policies and clinical practices when using occupational X-ray during ablation procedures and device implantation. This survey shows infrequent use of lead gloves, radiation absorbing pads, and lead glass cabins, but increasing use of three-dimensional mapping systems to decrease X-ray radiation hazards. Digital fluoroscopy with decreased frame rate is not used by approximately one-third of responding centres.
5
Panos Vardas, Angelo Auricchio, Jean Jacques Blanc et al. · EP Europace · 2007 · 290 citations · Full text
Reducing operator radiation exposure during cardiac resynchronization therapy
Marco Brambilla, Eraldo Occhetta, M. Ronconi et al. · EP Europace · 2010 · 35 citations
Medicine, Cardiology, Radiology +16