MedicineImplant DentistryBiomechanicsBone AugmentationFinite Element AnalysisAbutment DesignBone BiomechanicsBone MechanicsImplant BiomechanicsImplant DesignImplant MaterialsBiomechanical EffectsBiomechanical Stress At Implant InterfaceBiomechanical Testing Of ImplantsImplant Abutment GeometryImplant Stress DistributionImplant-abutment InterfacePeri-implant Bone FormationStress Distribution
OBJECTIVES: The purpose of this study was to determine the influence of platform switching on stress distribution of two different implant systems using three-dimensional (3D) finite element models. MATERIALS AND METHODS: Six 3D finite element models were created to replicate two different implant systems with peri-implant bone tissue, in which six different implant-abutment configurations were represented: model XiVE-a: 3.8-mm-diameter implant and 3.8-mm-diameter abutment; model XiVE-b (platform-switching model): 4.5-mm-diameter implant and 3.8-mm-diameter abutment; model XiVE-c: 4.5-mm-diameter implant and 4.5-mm-diameter abutment; model 3i-a: 4.0-mm-diameter implant and 4.1-mm-diameter abutment; model 3i-b (platform-switching model): 5.0-mm-diameter implant and 4.1-mm-diameter abutment; model 3i-c: 5.0-mm-diameter implant and 5.0-mm-diameter abutment. vertical and oblique loads of 100 were applied to all models. RESULTS: While the pattern of stress distribution was similar for both loading situations, oblique loading resulted in higher intensity and greater distribution of stress than axial loading in both cortical bone and implant-abutment- interface. Stress distribution at peri-implant bone was almost identical with similar magnitudes for all six models. In both implant systems, platform-switching models demonstrated lower maximum von Mises stress in cortical bone than conventional models. However, in both implant systems and under both loading situations, platform-switching models showed higher stresses at the implant-abutment interface than conventional models. CONCLUSION: In both implant systems, platform switching design reduced the stress concentration in the crestal bone and shifted it towards the area of implant-abutment interface.
38
Dimension of the periimplant mucosa
Tord Berglundh, Jan Lindhe · Journal Of Clinical Periodontology · 1996 · 796 citations
Joachim S. Hermann, David L. Cochran, Pirkka V. Nummikoski et al. · Journal of Periodontology · 1997 · 677 citations · Full text
Joachim S. Hermann, John Schoolfield, Robert Schenk et al. · Journal of Periodontology · 2001 · 535 citations
David L. Cochran, Joachim S. Hermann, Robert Schenk et al. · Journal of Periodontology · 1997 · 502 citations